Tepco predicts cold shutdown at Fukushima units 1, 2 and 3 by year-end

28 September 2011


As work continues to cover unit 1, Tepco has predicted that it will be able to stabilise cooling of the damaged Fukushima Daiichi 1, 2 and 3 reactors by the end of the year, according to an interim progress report released in late September.

Tepco defines the conditions of cold shutdown as a reactor pressure vessel bottom temperature of below 100°C 'in general', radioactivity release from the primary containment vessel is 'under control', and public exposure from additional radioactive releases are 'significantly held down.' As of 19 September, the RPV bottom temperature was 84°C at unit 1 (and temperatures are now being kept down below 100°C), 113°C at unit 2 and 91°C at unit 3. Core spray water injection (in addition to feedwater cooling) began at unit 3 on 1 September, and on 14 September for unit 2. Water injection amounts are 3.6m3/hr at unit 1, 7.6m3/hr at unit 2 and 12m3/hr at unit 3, according to Tepco.

A frame for unit 1 has been completed, and panels are now being installed. Work to remove radioactive debris from the top of unit 3 began in September.

The current radioactive release rate at the site is 0.2 billion Bq/hr, consisting of 0.04 billion Bq/hr from the top of unit 1, the same from unit 2, an undisclosed amount from unit 3, and 0.13 billion Bq/hr in the breakwater area. A provisional estimate of site boundary exposure is 0.4 mSv per year.

Contaminated water treatment has reached its short-term goal of reduction to 3m above Ohama port levels, at which point the system can withstand heavy rain and prolonged outage without leaking, Tepco said. It said that 95 000 tons had been processed as of 18 September.

Tepco also plans to install a primary containment vessel gas control system in units 1-3 after core temperatures drop below 100°C. As nitrogen is injected into the PCVs, a similar amount of gas will be extracted, dehumidified, filtered, monitored and then discharged. The goal is to maintain PCV pressure at atmospheric levels. PCV (drywell) pressures as of 21 September were 0.1226 MPa, 0.112 MPa and 0.1015 MPa in units 1-3, according to Japan Atomic Industrial Forum's Atoms in Japan news service. (Standard atmospheric pressure is 0.1013 MPa.)

Mid-term plans are currently under review by the government regulator.

Regular updates may be found on the website of our sister journal, Nuclear Engineering International, reachable on <www.neimagazine.com> or by clicking on the link in the navigation bar to the left of this page.

The following sites are also posting continuing updates:

<http://www.tepco.co.jp/en/index-e.html>

<http://www.iaea.org/>

<http://www.jaif.or.jp/english/>

<http://bravenewclimate.com/2011/03/15/tepco-reactor-status/>

<http://www.world-nuclear-news.org/>

<http://www.kantei.go.jp/foreign/index-e.html>




Linkedin Linkedin   
Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.